PECSOFLEX ® 450/750 V

DESCRIPTION

FLEXIBLE FIRE RETARDANT PVC INSULATED AND SHEATHED CABLE WITH LOW EMISSION OF HALOGENIDRIC GASES

SHAPE

Round

INSTALLATION

Mobile

CONDUCTOR

Flexible annealed copper cord, class 5 (EN 60228, IEC 60228)

INSULATION

Polyvinyl chloride compound with a low emission of smoke and corrosive gases at a max temperature of 80°C, with rated voltage 450/750 V and special requirements of reaction to fire performance according to the Construction Products Regulation (CPR) and in compliance to VDE 0207-363-3 and EN 50363-3

SHEAT

Polyvinyl chloride compound for cables with rated voltage Uo/U 450/750 V, according to Fire reaction classes required by the Construction Products Regulation (CPR) and in compliance to VDE 0207-363-4.1 and EN 50363-4.1

MAX MECHANICAL STRESS

5 Kg/mm²

MARKING

Ink Jet: PECSOFLEX® 450/750 V (section) OIL BARRIER UV + Water Resistant Cca s3, d1, a3 IEC EN 60332-3-24 CE Made in Italy w/y (meters)

COLOR

Cores identification according to CENELEC HD 308 in force.

VOLTAGE

450/750 V

MAXIMUM TEMPERATURE ON USE

80 ºC

MINIMUM TEMPERATURE OF INSTALLATION

-20 ºC mobile pose | -40 ºC fixed pose

MAXIMUM SHORT CIRCUIT TEMPERATURE

150° C

STANDARDS

VDE 0207-363-4.1, VDE 0207-363-3, EN 50363-4.1, EN 50363-3, EN 50575:2014+A1:16, IEC EN CEI 60332-3-24, IEC EN 60228, ISO 4892-2-2013, IEC EN 60811-404

MINIMUM INTERNAL BENDING RADIUS

4xD

CERTIFICATIONS

click on the logos to download the certification

Guide to use

Innovative cable, very flexible, 450/750 V, “oil barrier” suitable for general use in environments with possible contact with industrial oils.
Cable suitable for connections on the machine, for the power supply of industrial machines and machine tools, in the industrial sector and in general production activities.
Optimal use for connections that require reduced dimensions for use in confined spaces.
UV resistant cable for outdoor applications
Fire retardant cable and also suitable for applications not subject to CPR regulation: non continuosly flexing installation.
Not allowed direct burial and ducting buried undergroud.
This cable can be installed with other 450/750 V cables.

Cable compliant to CPR. Oil Barrier: oil resistance test carried out at the Pecso laboratory for 4 h at 40 ° C with IRM902 in accordance with IEC EN 60811-404. UV Resistant: tests conducted in an external laboratory certifiyng colour stability and mechanical properties after ageing