H05VV5-F
DESCRIPTION
PVC INSULATED AND SHEATHED OIL RESISTANT CABLE
SHAPE
Round
INSTALLATION
Mobile
CONDUCTOR
Flexible annealed copper cord, class 5 (EN 60228, IEC 60228)
INSULATION
Thermoplastic polyvinyl chloride compound TI2 type. Electrical insulation of cables for mobile connections.
SHEAT
Elastomeric polyvinyl chloride compound type TM5. Protective sheath of oil-resistant cables, for fixed laying and mobile connections.
MAX MECHANICAL STRESS
5 Kg/mm²
MARKING
Ink jet: PECSO MN IEMMEQU HAR H05VV5-F (SECTION) CE Eca
COLOR
Cores identification: black numbered + green/yellow
VOLTAGE
300/500 V
MAXIMUM TEMPERATURE ON USE
60 ºC
MINIMUM TEMPERATURE OF INSTALLATION
5º C
MAXIMUM SHORT CIRCUIT TEMPERATURE
150° C
STANDARDS
EN 50525-2-51 ROHS 2011/65/UE EN50575:2014 + A1
MINIMUM INTERNAL BENDING RADIUS
9xD
CERTIFICATIONS
click on the logos to download the certification
Guide to use
Suitable for interconnection of parts of manufacturing machines including machine tools. Indoor use with applications requiring general mineral oils resistance. Temporary short-term outdoors use allowed. Cable can be moved after installation – especially for relocation, maintenance, regulation and checking of machinery – provided that any possible mechanical stress caused is avoided. Installation in pipes, conduits or similar is recommended if no displacement is required. Contamination by hydrocarbons, acids and alkali shall be avoided.
Cables shall be protected against mechanical damage. In case of possible contact with special oils seek for manufacturer advice. Max strain in static duty conditions: 1,5 Kg/mm². Flame retardant.
ACCORDING TO CPR CLASS Eca: Cables for general applications in construction works subject to fire resistance requirements. Provided by EN 50575: 2014 + A1.
Declaration of performance: DOP 00027.
HARMONIZED CABLE: With oil resistant sheath.